Minilab IQ PRO pack (+ Bluetooth Thermal Printer)
The Minilab IQ Pro Pack includes the Minilab IQ Fuel Cell Breathalyzer with a Blue tooth Thermal Printer to create a record of each test that can be signed by the tester and test subject along with duplicate copies. Ideal for workplace or clinic testing where a record is required. Everyting you need to start screening is included.
whats included :
- Minilab IQ Fuel Cell Breathalyzer - Professional Grade Sensor.
- Thermal Bluetooth Printer ( Rechargable & Fully Mobile)
- 4 x Printer Rolls ( enough for hundreds of results)
- 50 Mouth Peices
- Charger Cable for Printer & Device
Why the Minilab IQ?
Features at a glance:
- A Professional Garda Grade Breathalyzer designed for the Irish User – Calibrated to Irish Legal Limits.
- Superior Fuel Cell Sensor – Garda grade. More reliable than a semi-conductor breathalyzer.
- Color Alert System Preprogrammed for Irish Drink Driving Limits
- Full Rechargeable Lithium Battery.
- Serviced & Calibrated in Ireland within 24 hours or NEW replace the sensor at home.
- Records previous 2000 test results
- Change the measurement unit to suit your requirements
- Breath flow capture. Ensuring a sufficient breath sample every time.
- Customizable settings & advanced features. Read on for full details.
Minilab IQ Pro Pack – Professional Fuel Cell System with Bluetooth Thermal Printer
Professional-Grade Fuel Cell Technology
Minilab IQ Pro Pack features a European-made fuel cell sensor, using the same core technology trusted by Irish Gardaí and police forces worldwide. This alcohol-specific sensor delivers the level of accuracy expected in professional and workplace environments.
Serviceable Instrument with Irish Calibration & Certification
The device is fully calibrated and serviced here in Ireland. Organisations can choose professional calibration with certification issued, or replace the fuel cell sensor and obtain an accuracy certificate with each sensor change. This provides documented evidence of maintenance and performance for compliance and audit purposes.
Printed Test Records for Compliance & Accountability
The included Bluetooth-enabled thermal printer allows instant printing of test results. A printed record supports internal compliance procedures, provides traceability for workplace testing programmes, and enables results to be shared clearly between managers or departments. In clinical or treatment environments, printed results can be retained as part of structured monitoring protocols.
Complete Professional Kit – Ready to Deploy
The Pro Pack includes everything required to begin testing immediately:
Minilab IQ fuel cell breathalyser
Bluetooth thermal printer
Hard protective carry case
Printer paper rolls
Charging cables
50 mouthpieces
Note : This is a screening device only - for medico-legal testing please contact us for options.


Accuracy
European-Made Fuel Cell Sensor Technology
The new Minilab IQ features a European-made fuel cell sensor, using the same core technology trusted by Irish Gardaí and police forces worldwide. This professional-grade sensor is alcohol-specific, meaning it reacts only to ethanol and not to external contaminants.
Fuel cell technology delivers superior accuracy and stability across a wide range of BAC levels. Unlike semiconductor devices, which can be influenced by temperature, humidity or other airborne substances, fuel cell sensors maintain precision even at higher alcohol concentrations. Semiconductor units may also respond to non-alcohol compounds, potentially producing unreliable readings. Fuel cell systems are engineered specifically to avoid this.
Breath Flow Capture Control
Minilab IQ is designed to capture a deep-lung air sample for every test, helping prevent underestimation of results. The device monitors breath flow in real time and will prompt the user to repeat the test if a sufficient sample is not obtained. This ensures consistency, reliability and user confidence with every reading.


Colour Alerts & Results to 3 Decimal Places
Minilab IQ displays results to 3 decimal places in mg/L, providing detailed and accurate measurement aligned with Irish drink-driving limits.
In addition to the precise numerical reading, the device incorporates a colour-coded alert system. The LCD screen and warning indicator illuminate at defined thresholds relevant to Irish legal limits:
0.09 mg/L – Learner, Novice and Professional Drivers
0.22 mg/L – All Other Drivers
This dual system provides both exact measurement and immediate visual reference.
At the time of publishing this page (02/02/26), the above drink-driving limits apply in Ireland.
Measurement units can be adjusted in the device settings to suit your preferred reading format.
Colour-coded alert levels can also be customised within the settings, allowing you to set warnings at levels you consider appropriate for your own safety margin.
Important Notice
Alcohol level is not an indication of impairment. Reaction time, judgement and coordination may be affected even at low readings.
Alcohol levels may continue to rise after your last drink. A later test may produce a higher result.
Never drink and drive. The only safe limit is zero.
For screening purposes only. Not intended to determine fitness to drive.


Built-In Service Reminder
Minilab IQ includes an integrated calibration and sensor-change reminder. The device will notify you after 500 tests, prompting you to arrange calibration or replace the sensor.
While the European-made fuel cell sensor is designed for long operational life and may continue functioning beyond this point, all serious breathalysers require periodic servicing to maintain accuracy. Over time, sensors naturally drift and measurement precision can reduce.
For optimal performance, we recommend calibration or sensor replacement at least every 12 months, or sooner depending on frequency of use.


Rechargeable.
This breathalyzer is fully rechargeable with the new version Android phone charger type ( cable included, plug not included). This device has a built-in large -capacity lithium battery, which can provide you with a standby time for up to one month after full charging. This device uses the USB Type-C standard charging interface, or you can use the national standard Type-C 5V charging ornament or charger to charge but charging with an inferior charging adapter may cause product failure and damage. The minilab h3 breathalyzer has a battery indicator on the screen at all times.


Replaceable Sensor – An Alternative to Calibration
Minilab IQ features a user-replaceable European-made fuel cell sensor module. The sensor can be replaced at home quickly and easily, without specialist tools.
Sensor replacement provides a convenient alternative to sending the device in for calibration. It allows you to restore performance quickly and extend the working life of the unit without downtime.
Full sensor replacement kit (for at-home installation): €29.99
All pricing in euro.
Service & Calibration in Ireland
Minilab IQ is fully serviced and calibrated in Ireland. Standard calibration turnaround is 1 business day, with typical door-to-door shipping typically completed within approximately 3 business days.
A permanent calibration record is maintained for your device, ensuring documented service history and traceability.
Calibration is recommended every 200 uses or every 6 to 12 months, depending on frequency of use.
You may send your device to us at any time for a free assessment to determine whether calibration is required.
Calibration service: €19.99


Memory.
Minilab IQ stores up to 2000 test results in internal memory, allowing you to review previous readings directly on the device.
A record of the most recent calibration is also stored for reference, providing visibility of the device’s service status.
Users may find it useful to track food and alcohol consumption alongside recorded results. Reviewing this information over time can help build awareness of how alcohol levels vary under different conditions.

Advanced display & settings :
- Password protected settings ensure only authorised users can adjust device configuration.
- Customisable colour alert levels allow you to set warning thresholds to your preferred safety margin.
- Selectable measurement units enable results to be displayed in multiple formats, including breath alcohol (mg/L) and blood alcohol equivalents (BAC), depending on your preferred reading method.
- Adjustable breath flow capture sensitivity allows the countdown and sampling threshold to be modified, making it easier to provide a sample where required.
- Bluetooth enabled for optional wireless printing.
- User-adjustable date and time settings.
- Clear on-screen battery level indicator, with time and date displayed at all times.
- Master cut-off power switch prevents accidental activation when the device is stored.
- Automatic power-off after 2 minutes of inactivity to preserve battery life.
- Valved mouthpieces are designed to help prevent debris and moisture from entering the sensor chamber.

1-year warranty
Minilab IQ includes a 1-year repair or replacement warranty covering manufacturing defects.
The warranty is activated automatically from the date of purchase.
This warranty covers device faults arising from normal intended use. It does not cover accidental damage, misuse, or sensor degradation resulting from usage beyond recommended service intervals (500 tests or 6–12 months, whichever comes first). Damage caused by blowing raw alcohol directly into the sensor is also excluded.
All warranty assessment and service is carried out in Ireland.
Inbound shipping to Minilab is not included under warranty.
DISCLAIMER
The Minilab IQ is a consumer screening device intended solely to provide an estimate of breath alcohol concentration (BrAC) at the time of testing for personal informational purposes. It is not an evidential instrument and is not certified or approved for legal, law enforcement, workplace disciplinary, or court-admissible use.
The device does not determine intoxication, impairment, or fitness to drive or operate machinery. Results must not be used to decide whether a person should drive, operate machinery, or engage in any activity requiring alertness or legal compliance. A low, “LO,” or zero reading does not guarantee the absence of impairment, unimpaired judgement, safe reaction time, or compliance with legal limits. The only safe level of alcohol for driving is zero. This device must never be used to justify drinking and driving.
Results displayed are estimates based on breath alcohol concentration and may not precisely reflect blood alcohol concentration (BAC). Breath alcohol readings are influenced by numerous factors including, but not limited to, recent alcohol consumption, residual mouth alcohol, food intake, smoking, use of mouthwash or oral products, environmental alcohol vapours, temperature, humidity, improper breath technique, improper storage, or failure to follow operating instructions.
To reduce the risk of inaccurate readings, users must wait at least 20–30 minutes after consuming alcohol, eating, smoking, or using oral products before testing. Testing too soon may result in artificially elevated or inaccurate readings and may damage the sensor.
This device uses fuel-cell sensor technology designed to detect ethanol specifically. While fuel-cell technology significantly reduces cross-sensitivity compared to semiconductor sensors, the presence of non-ethanol alcohols (including but not limited to methanol or isopropanol) or certain volatile organic compounds in high concentrations may influence readings.
Certain medical or physiological conditions, including but not limited to diabetes, ketosis, ketoacidosis, or other metabolic states, may produce breath compounds that could affect readings. Users with medical conditions should consult a qualified professional regarding interpretation of results.
Alcohol levels may continue to rise for several hours after drinking has ceased. A test result reflects alcohol concentration only at the precise time of testing and does not predict future levels.
Alcohol limits vary by country and jurisdiction. Users are solely responsible for understanding and complying with all applicable laws and legal thresholds in their region. Alert thresholds within the device are user-configurable and do not alter or replace legal limits.
Like all precision instruments, the device requires periodic calibration and, where applicable, sensor replacement to maintain performance. Failure to calibrate at recommended intervals may result in inaccurate readings. The device must not be used without a mouthpiece if specified in the instructions, as improper use may damage the sensor and affect accuracy.
The product is provided “as is” subject only to applicable statutory warranties. To the fullest extent permitted by law, the manufacturer and distributors disclaim all liability for any direct, indirect, incidental, consequential, special, punitive, or exemplary damages, including but not limited to personal injury, property damage, financial loss, legal penalties, prosecution, licence suspension, or other consequences arising from use of or reliance on the device or its readings.
By purchasing or using this device, the user acknowledges that they have read and understood the operating instructions and this disclaimer, and accept full responsibility for all decisions and actions taken following its use.
Nothing in this disclaimer excludes or limits rights that cannot be excluded under applicable consumer protection laws.
For legal or evidential determination of blood alcohol concentration, approved and certified testing methods must be used.
| Price | €249.99 |
|---|













